Real-time monitoring of DO, pH, ammonia, nitrite, TSS, and alkalinity | Maintain optimal C/N ratios, reduce nitrogenous waste, improve FCR
Request QuotePeru's aquaculture sector is rapidly adopting Biofloc Technology (BFT) for Nile tilapia (Oreochromis niloticus) production. BFT is an environmentally sustainable system that converts nitrogenous waste (ammonia, nitrite) into microbial protein, reducing water exchange and providing supplemental nutrition to fish. In BFT, a C/N ratio of ~15–20 is maintained by adding organic carbon (e.g., molasses, glucose) to promote heterotrophic bacteria growth, which assimilate ammonia into biofloc particles. Studies show biofloc can contribute up to 25% of tilapia's protein requirements, improving feed conversion ratios (FCR) and reducing feed costs .
BFT systems can experience ammonia (>1.5 mg/L) and nitrite (>0.5 mg/L) surges without real-time monitoring, requiring immediate carbon supplementation.
Biofloc systems require 24/7 aeration. DO below 4 mg/L stresses fish and slows nitrification. Optimal DO: 4.67–5.02 mg/L.
Total Suspended Solids (TSS) >1000 mg/L or FV₃₀ >50 mL/L requires floc removal. Manual testing delays corrective action.
Traditional methods test ammonia/nitrite daily or weekly. Missed fluctuations lead to suboptimal carbon dosing and poor FCR.
| Parameter | Critical Role in BFT | Target Range |
|---|---|---|
| Dissolved Oxygen | Fish respiration & nitrification; 24/7 aeration | >4.0 mg/L |
| pH | Affects ammonia toxicity & nitrification rate | 6.5–8.0 |
| Ammonia (TAN) | Trigger for carbon dosing (glucose/molasses) | <1.5 mg/L |
| Nitrite (NO₂⁻) | Indicator of nitrification imbalance | <0.5 mg/L |
| TSS / FV₃₀ | Biofloc concentration; affects oxygen demand | 25–50 mL/L |
| Alkalinity | Buffers pH; critical for nitrifying bacteria | 130–160 mg/L CaCO₃ |
✔ Up to 6 channels | Compatible with digital sensors for BFT water
GWQ-MP200 Controller + Digital Sensors
RS485 to farm SCADA / PLC
6 relays → carbon dosing pumps / aeration alarms
Real installations: biofloc ponds, control rooms, and sensor deployment
📊 GWQ-MP200 monitoring BFT parameters in farm control room
🔧 Results After 8 Months - Piura BFT Tilapia Farm
📱 Real-time BFT parameter dashboard on mobile
Actual deployment: BFT tilapia farms in Lima and Piura regions — contact us for more photos
This 5,000 m² BFT facility in Piura produces Nile tilapia for domestic and export markets. Before upgrading, the farm relied on daily manual testing of ammonia, nitrite, pH, and DO — missing nighttime and post-feeding fluctuations. Ammonia spikes (>2.5 mg/L) occurred weekly, requiring emergency carbon dosing and causing stress-related mortality. FCR averaged 1.8, above industry benchmarks. TSS/FV₃₀ was tested weekly, often exceeding 60 mL/L before corrective action.
Installed one GWQ-MP200 with 6 digital sensors: DO, pH, ammonia, nitrite, TSS, and alkalinity. Integrated with existing aeration and carbon dosing pumps via RS485 (Modbus-RTU). Configured relays for: ammonia >1.5 mg/L → carbon pump activation; DO <4.0 mg/L → aeration alarm; FV₃₀ >50 mL/L → floc removal alert.
| Parameter | Specification |
|---|---|
| Measurement channels | 1 to 6, any parameter combination |
| Outputs | 2x isolated 4-20 mA (load <750Ω) |
| Communication | 2x RS485 (Modbus-RTU) |
| Relays | 6 relays, 250VAC/3A |
| Data storage | TF card 8GB (max 32GB) |
| Installation | Main unit: wall-mount; Sensors: immersion/thread |
| Dimensions | 223×200×120 mm |
| Power supply | 100–250 VAC, 50/60Hz |
※ Compatible with digital sensors for BFT, seawater, and freshwater applications
When ordering, please provide: number of channels, parameter types per channel, measurement ranges, and sensor cable length. Our engineers will recommend the optimal sensor suite for your biofloc tilapia operation.
* GWQ-MP200 only works with GAIMC digital sensors — consult sales for complete system compatibility.