💨 Application Scenarios: Wet FGD absorber tower slurry monitoring, gypsum dewatering wastewater, blowdown treatment & final discharge compliance
📅 Implementation: 2024 – present | Equipment: GAIMC GWQ-MP200 Multi-parameter Water Quality Analyzer (supports pH/ORP/Conductivity/Turbidity/Residual Chlorine, digital sensors)
| Parameter | FGD Application Value | GWQ-MP200 Capability |
|---|---|---|
| 💧 pHOptimal SO₂ absorption (pH 5.0–6.0); avoids scaling, corrosion, and lime overuse | Supports 1–6 channels flexible combination, plug-and-play digital sensors | |
| ⚡ Conductivity / TDSIndicates slurry density and gypsum saturation; controls blowdown to prevent scaling | ||
| 🔋 ORP (Oxidation-Reduction Potential)Monitors oxidation of sulfite to sulfate; ensures proper air/O₂ supply | ||
| 🌫️ TurbidityDetects solids carryover in gypsum dewatering and blowdown stream | ||
| 🧪 Residual ChlorineDisinfection control for recycled or discharge water (where chlorination applied) | ||
| 🌡️ Temperature (Auto-compensated)Compensates pH/conductivity readings; monitors process thermal stability | ||
| ✅ Multi-channel isolated 4-20mA outputs + 2 RS485 Modbus-RTU + relay control for automated lime dosing and blowdown valves | ||
🎛️ Tailored for FGD
Dedicated configuration: pH + ORP + Conductivity + Turbidity — covers all critical scrubber control and wastewater parameters.📲 Seamless DCS Integration
2x RS485 Modbus-RTU and 4-20mA outputs directly connect to plant DCS for real-time trending and automated lime/limestone slurry control.💾 Environmental Data Traceability
8GB TF card (up to 32GB) stores years of operational data for audits and process optimization.
- SO₂ removal efficiency increased from 94% to 98.5% (well above India's CPCB standard of 90%);
- Lime/limestone consumption reduced by 22% thanks to precise pH control (±0.1 pH stability);
- Scaling-related downtime decreased by 65% due to density/conductivity-based blowdown optimization;
- Zero environmental non-compliance incidents on blowdown discharge (pH 6–9, turbidity < 30 NTU).
✅ High-reliability real-time OS, touch configuration & automatic temperature compensation for harsh FGD environments.
✅ Multi-channel isolated 4-20mA outputs (load < 750Ω) + two RS485 Modbus-RTU for seamless DCS integration.
✅ Relay control directly drives lime feeders, blowdown valves, and alarms. Wide power supply 100-250VAC.
✅ Wall-mount main unit (223*200*120mm) + immersion/threaded electrodes. Sensors available in abrasion-resistant materials for high-solids slurry.
✅ Expandable parameters: pH, ORP, conductivity, dissolved oxygen, residual chlorine, turbidity, COD, ammonia, etc. Future-ready for stricter discharge norms.
- Absorber tower loop (4 channels): pH + ORP + Conductivity + Temperature — core parameters for SO₂ absorption efficiency and scaling prevention;
- Blowdown / wastewater discharge (3 channels): pH + Turbidity + Residual Chlorine — ensures compliance with local discharge standards (e.g., CPCB norms);
- Optional for gypsum dewatering: additional turbidity channel to monitor filtrate clarity.
📐 GWQ-MP200 FGD System Architecture
Real-time multi-parameter monitoring + automated control for optimal desulfurization efficiency and discharge compliance
Contact us now for GWQ-MP200 FGD configuration list & detailed case report