Charging gun · charging pile · charging station — integrated monitoring of gun-body temperature rise, liquid-cooled cable loops, power cabinet hotspots, busbar joints, ESS cabin safety and unattended site telemetry.
Thermal pressure in high-power supercharging concentrates at three spots: the gun pins and liquid-cooled cable flow channels, the SiC/IGBT modules inside the power cabinet, and the busbar joints across the station. The higher the current, the faster the temperature rise — while outdoor exposure to sunlight, sudden thermal cycling and condensation accelerates insulation degradation.
GAIMC deploys its temperature, flow and water-quality product families across three levels — gun, pile and station: gun-body and pin temperature rise; coolant temperature and flow; module baseplate temperature and cabinet temperature/humidity; coolant conductivity and pH; and busbar joint temperature. All data is gathered via 4–20mA / RS485 and 4G into the station control cabinet, then integrated into the site EMS and cloud platform.
Early AC piles and air-cooled DC machines rely on coarse thermal cutoff switches with few sensing points — they can't see junction temperatures or transient pin temperature rise.
Most liquid-cooled units have no online working-fluid monitoring — periodic sampling means corrosion and insulation degradation are found only after damage is done.
Equipment running at full load for years develops stress relaxation and oxidation at busbar and cable compression joints — a classic hidden heat source.
Supercharging guns leave little room for probes: sensors must survive insertion vibration and high voltage while routing through the cable to the pile.
Parking bays are scattered; trenching cable across traffic lanes is expensive and vulnerable to stray-current interference.
From November 2026, sites without coordinated flow-and-junction-temperature regulation will also face energy-efficiency assessment.
GAIMC combines its track record in industrial temperature measurement, low-flow measurement and water-quality analysis to arrange monitoring points at gun level, pile level and station level. Each node collects locally, merges through shielded twisted pairs and bus isolation into the station control cabinet, and then feeds the site EMS and cloud platform.
| Level | Monitoring Targets & Configuration |
|---|---|
| Gun Level | Liquid-cooled gun head pins, large-current contact surfaces, coolant in/out flow channels and cable · GTT200 / GTT210H compact pin/duct temperature · GUF300 clamp-on ultrasonic flow (DN15–25) · GTS300 twist-tip sealed platinum sensors |
| Pile Level | SiC/IGBT power modules, water-cooled baseplates, cabinet climate · GTS300 film platinum sensors (patch / clamp type) · GTT210S waterproof micro T&H transmitters · GTT210S water in/out differential temperature · GTHT310 (duct series) / GTHT391 micro T&H |
| Station Level | Transformer-cable terminations, switchgear breaker contacts, cables · CDU and ESS battery cabins · GWC-EC200 / GEC-EC485 online conductivity · GWQ-pH6.0 industrial pH (anti-corrosion) · GUF120A-W external flow + GTT210B isolated temperature |
| Data Aggregation | Isolated RS485 (Modbus-RTU) / CAN 2.0B / 4–20mA · GWM300 industrial 4G DTU · GPR200 paperless recorder for local evidence and incident backfill · two-stage protection logic: derate at first threshold, trip at second |
| EMS / Cloud | Full-station thermal risk profile broken down by gun–pile–station chain · GB 46519-2025 energy-efficiency readiness · predictive maintenance via coolant aging analytics · OCPP / third-party EMS interconnection |
GTS100 thermistor probes are embedded in the gun-head terminal block, directly against the DC+/DC- pins; GTS300 patch platinum sensors mount on the gun inner wall and cable crimp joints. Wiring runs through the gun harness and cable cores to GTT210S converters — pin contact degradation and crimp loosening are caught during charging, not by hand-feel at full power.
GTT200 / GTT210H measure pin socket and coolant in/return channel temperatures; GUF300 clamp-on flow meter attaches externally to the return hose without cutting the line — cable and pin temperature rise are readable in real time, and any flow drop triggers an alarm.
GTS300 film platinum sensors bond to SiC/IGBT water-cooled baseplate faces; GTT210S tracks cooling water in/out differential temperature; GTHT310 / GTHT391 watch cabinet temperature and humidity — module junction temperature and cabinet condensation are controlled at the same time.
GTS100 ring probes are clamped by the busbar bolt over each copper-bar overlap point; GTS300 threaded probes screw into liquid-loop tees with hex-seal seating; GTHT391 micro transmitters wall-mount inside the cabinet — busbar joints, coolant temperature and cabinet climate collected in one cabinet, locating the overheating segment without guesswork.
GWQ-EC200 and GWQ-pH6.0 electrodes screw into the flow channel through tee riser ports — conductivity or pH excursion prompts coolant replacement before insulation breaks down.
GTS300 copper-nose probes are pressed by the same compression bolt as busbar and cable terminations, converted by GTT210H / GTT210B — heating caused by rising contact resistance is detected early, before insulation damage.
GTT200 measures CDU supply/return water temperature; GUF120A-W clamp-on sensors align to the pipe centerline externally; GTHT350 watches the ESS cabin climate; GPR200 records locally — cooling capacity is computed from differential temperature and flow, and cabin over-temperature alarms on the spot.
GTHT318 radiation shields mount on cabinet roofs with cables into GWM300 terminals; GTT280 measurement probes screw directly into pipe bosses and upload via 4G — scattered nodes go wireless, site climate and pipe temperatures are readable remotely.
| Category | Specification |
|---|---|
| Temperature | Coverage -50 ~ +200℃ · Class A Pt100/Pt1000, accuracy ±0.2℃, T90 ≤ 1.5 s · embedded NTC in gun-head terminal blocks, patch platinum on gun walls and crimp joints · wiring inside the gun body, routed through cable cores · vibration-resistant, IP67 |
| Flow | DN15 ~ DN300 · external clamp-on ultrasonic, accuracy better than ±1.0% · velocity floor 0.01 m/s |
| Water Quality | Conductivity 0.05 ~ 200.0 μS/cm, resolution 0.01 μS/cm · electrodes pressure-rated 1.0 MPa with temperature compensation · pH online with anti-corrosion electrode |
| Environment | Temperature accuracy ±0.3℃, humidity ±2% RH · protection IP65/IP67 |
One system for temperature, flow and water quality — gun-body temperature rise, pin temperature and coolant condition are judged against each other, so contact degradation and fluid degradation can't mask each other.
No pipeline shutdown for retrofit — GUF300 and GUF120A-W are external clamp-on; GTS300 uses clamp or compression mounting. Existing stations are upgraded without opening the liquid-cooling main loop.
Standard products only — sensors and transmitters are all GAIMC catalog items; procurement and spares stay unified across the fleet.
Energy-efficiency ready — cooling-capacity data supports pump and fan speed regulation, meeting the GB 46519-2025 efficiency requirements.
Full traceability — continuous records support acceptance testing and incident forensics.
Can we retrofit existing liquid-cooled superchargers without draining the coolant loop?
Yes. GUF300 and GUF120A-W clamp onto the outside of pipes and hoses — no line cutting, no draining. GTS300 sensors use clamp or bolt-compression mounting. A typical pile retrofit is completed in a single maintenance window.
How do the sensors survive gun insertion vibration and high voltage?
Gun-head probes are embedded in the terminal block or patched inside the gun body, with all wiring routed inside the gun and through cable cores to the pile-side converter. Probes are rated IP67 and specified for repeated insertion cycles under high-current conditions.
Does this help with GB 46519-2025 compliance?
The standard takes effect from November 2026 and requires coordinated flow and junction-temperature regulation plus energy-efficiency assessment. This solution collects exactly that dataset — coolant flow, module temperatures and cooling capacity — and supports the two-stage derate/trip protection logic.
How do we know when to replace the coolant?
GWQ-EC200 conductivity and GWQ-pH6.0 pH electrodes monitor the working fluid continuously. When conductivity or pH crosses the alarm threshold, the platform prompts coolant replacement — before insulation resistance drops, not after corrosion appears.
Can the data feed our existing EMS or charging-network platform?
Yes. Field data merges via isolated RS485 (Modbus-RTU), CAN 2.0B or 4–20mA into the station control cabinet, and the platform side supports OCPP and third-party EMS interconnection. GWM300 4G DTU covers sites without wired backhaul.
How do you monitor busbar joints without shutting down the station?
GTS300 copper-nose probes share the existing compression bolt of each termination — installation is mechanical only, no electrical rework, and measurement runs live from the moment of installation.
Send us your pile models and station layout — GAIMC engineers will return a gun/pile/station point list and quotation.
Rm. 1208, Building B, Huixin IBC, No. 1 Zhang Bayi Road, High-tech Zone, Xi'an, Shaanxi, China
Copyright © Xi'an Gavin Electronic Technology Co., Ltd Site Map